DC Field | Value | Language |
---|---|---|
dc.contributor.author | Y J Bae | - |
dc.contributor.author | K M Park | - |
dc.contributor.author | S H Ahn | - |
dc.contributor.author | Jeong Hee Moon | - |
dc.contributor.author | M S Kim | - |
dc.date.accessioned | 2017-04-19T09:55:32Z | - |
dc.date.available | 2017-04-19T09:55:32Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 1044-0305 | - |
dc.identifier.uri | 10.1007/s13361-014-0919-7 | ko |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/12134 | - |
dc.description.abstract | Previously, we reported that MALDI spectra of peptides became reproducible when temperature was kept constant. Linear calibration curves derived from such spectral data could be used for quantification. Homogeneity of samples was one of the requirements. Among the three popular matrices used in peptide MALDI [i.e., α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (DHB), and sinapinic acid (SA)], homogeneous samples could be prepared by conventional means only for CHCA. In this work, we showed that sample preparation by micro-spotting improved the homogeneity for all three cases. | - |
dc.publisher | Amer Soc Mass Spectr | - |
dc.title | Spectral reproducibility and quantification of peptides in MALDI of samples prepared by micro-spotting | - |
dc.title.alternative | Spectral reproducibility and quantification of peptides in MALDI of samples prepared by micro-spotting | - |
dc.type | Article | - |
dc.citation.title | Journal of American Society for Mass Spectrometry | - |
dc.citation.number | 8 | - |
dc.citation.endPage | 1505 | - |
dc.citation.startPage | 1502 | - |
dc.citation.volume | 25 | - |
dc.contributor.affiliatedAuthor | Jeong Hee Moon | - |
dc.contributor.alternativeName | 배용진 | - |
dc.contributor.alternativeName | 박경만 | - |
dc.contributor.alternativeName | 안성희 | - |
dc.contributor.alternativeName | 문정희 | - |
dc.contributor.alternativeName | 김명수 | - |
dc.identifier.bibliographicCitation | Journal of American Society for Mass Spectrometry, vol. 25, no. 8, pp. 1502-1505 | - |
dc.identifier.doi | 10.1007/s13361-014-0919-7 | - |
dc.subject.keyword | Homogeneity | - |
dc.subject.keyword | MALDI | - |
dc.subject.keyword | Micro-spotting | - |
dc.subject.keyword | Quantification | - |
dc.subject.keyword | Reproducibility | - |
dc.subject.local | Homogeneity | - |
dc.subject.local | MALDI | - |
dc.subject.local | Micro-spotting | - |
dc.subject.local | quantification | - |
dc.subject.local | Quantification | - |
dc.subject.local | Reproducibility | - |
dc.subject.local | reproducibility | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.