DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ji-Yeon Kang | - |
dc.contributor.author | Ohsuk Kwon | - |
dc.contributor.author | Jin Young Gil | - |
dc.contributor.author | Doo-Byoung Oh | - |
dc.date.accessioned | 2017-04-19T10:19:48Z | - |
dc.date.available | 2017-04-19T10:19:48Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0003-2697 | - |
dc.identifier.uri | 10.1016/j.ab.2016.02.004 | ko |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/13211 | - |
dc.description.abstract | Mannose-6-phosphate (M-6-P) glycan analysis is important for quality control of therapeutic enzymes for lysosomal storage diseases. Here, we found that the analysis of glycans containing two M-6-Ps was highly affected by the hydrophilicity of the elution solvent used in high-performance liquid chromatography (HPLC). In addition, the performances of three fluorescent tags - 2-aminobenzoic acid (2-AA), 2-aminobenzamide (2-AB), and 3-(acetyl-amino)-6-aminoacridine (AA-Ac) - were compared with each other for M-6-P glycan analysis using HPLC and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The best performance for analyzing M-6-P glycans was shown by 2-AA labeling in both analyses. | - |
dc.publisher | Elsevier | - |
dc.title | Comparison of fluorescent tags for analysis of mannose-6-phosphate glycans | - |
dc.title.alternative | Comparison of fluorescent tags for analysis of mannose-6-phosphate glycans | - |
dc.type | Article | - |
dc.citation.title | Analytical Biochemistry | - |
dc.citation.number | 0 | - |
dc.citation.endPage | 3 | - |
dc.citation.startPage | 1 | - |
dc.citation.volume | 501 | - |
dc.contributor.affiliatedAuthor | Ji-Yeon Kang | - |
dc.contributor.affiliatedAuthor | Ohsuk Kwon | - |
dc.contributor.affiliatedAuthor | Jin Young Gil | - |
dc.contributor.affiliatedAuthor | Doo-Byoung Oh | - |
dc.contributor.alternativeName | 강지연 | - |
dc.contributor.alternativeName | 권오석 | - |
dc.contributor.alternativeName | 길진영 | - |
dc.contributor.alternativeName | 오두병 | - |
dc.identifier.bibliographicCitation | Analytical Biochemistry, vol. 501, pp. 1-3 | - |
dc.identifier.doi | 10.1016/j.ab.2016.02.004 | - |
dc.subject.keyword | Fluorescent labeling tag | - |
dc.subject.keyword | Glycan analysis | - |
dc.subject.keyword | High-performance liquid chromatography (HPLC) | - |
dc.subject.keyword | Mannose-6-phosphate (M-6-P) | - |
dc.subject.keyword | Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry | - |
dc.subject.local | Fluorescent labeling tag | - |
dc.subject.local | Glycan analysis | - |
dc.subject.local | glycan analysis | - |
dc.subject.local | high-performance liquid chromatography | - |
dc.subject.local | High-performance liquid chromatography (HPLC) | - |
dc.subject.local | High-performance liquid chromatography | - |
dc.subject.local | Mannose-6-phosphate (M-6-P) | - |
dc.subject.local | Mannose-6-phosphate | - |
dc.subject.local | Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.