DC Field | Value | Language |
---|---|---|
dc.contributor.author | K M Park | - |
dc.contributor.author | S Yoon | - |
dc.contributor.author | Jeong Hee Moon | - |
dc.contributor.author | S H Lee | - |
dc.contributor.author | M S Kim | - |
dc.date.accessioned | 2017-04-19T10:23:20Z | - |
dc.date.available | 2017-04-19T10:23:20Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0253-2964 | - |
dc.identifier.uri | 10.1002/bkcs.10793 | ko |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/13310 | - |
dc.description.abstract | As part of the recently developed quantification method using matrix-assisted laser desorption ionization, matrix ion abundances are used to control the effective temperature, to construct a calibration curve, and to check the reliability of the quantification results. This method has not been used with commercial instruments owing to the difficulties in measuring the matrix ion abundances. In this work, we present a modification of each of the above guidelines to allow for quantification with commercial instruments. The modified method works with commercial instruments, which is partial proof for the validity of the method. | - |
dc.publisher | Wiley | - |
dc.title | Use of commercial MALDI-TOFs for analyte quantification by a newly invented method | - |
dc.title.alternative | Use of commercial MALDI-TOFs for analyte quantification by a newly invented method | - |
dc.type | Article | - |
dc.citation.title | Bulletin of Korean Chemical Society | - |
dc.citation.number | 6 | - |
dc.citation.endPage | 885 | - |
dc.citation.startPage | 882 | - |
dc.citation.volume | 37 | - |
dc.contributor.affiliatedAuthor | Jeong Hee Moon | - |
dc.contributor.alternativeName | 박경만 | - |
dc.contributor.alternativeName | 윤소희 | - |
dc.contributor.alternativeName | 문정희 | - |
dc.contributor.alternativeName | 이성훈 | - |
dc.contributor.alternativeName | 김명수 | - |
dc.identifier.bibliographicCitation | Bulletin of Korean Chemical Society, vol. 37, no. 6, pp. 882-885 | - |
dc.identifier.doi | 10.1002/bkcs.10793 | - |
dc.subject.keyword | Commercial instrument | - |
dc.subject.keyword | Liquid matrix | - |
dc.subject.keyword | MALDI quantification | - |
dc.subject.local | Commercial instrument | - |
dc.subject.local | liquid matrix | - |
dc.subject.local | Liquid matrix | - |
dc.subject.local | MALDI quantification | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.