Tracing the origin of the anomalous matrix suppression in matrix-assisted laser desorption ionization and extending the linear dynamic range during analyte quantification

Cited 2 time in scopus
Metadata Downloads

Full metadata record

DC FieldValueLanguage
dc.contributor.authorH I Song-
dc.contributor.authorT Hyeon-
dc.contributor.authorM S Kim-
dc.contributor.authorJ Y Oh-
dc.contributor.authorJeong Hee Moon-
dc.date.accessioned2018-04-19T05:18:58Z-
dc.date.available2018-04-19T05:18:58Z-
dc.date.issued2018-
dc.identifier.issn0253-2964-
dc.identifier.uri10.1002/bkcs.11368ko
dc.identifier.urihttps://oak.kribb.re.kr/handle/201005/17729-
dc.description.abstractIn the matrix-assisted laser desorption ionization-based quantification method developed in this laboratory, a linear calibration curve is constructed by plotting the analyte-to-matrix ion abundance ratio as a function of the analyte concentration. As the analyte concentration increases, however, the curve deviates from linearity. Previously, we observed that the occurrence of this deviation correlated with the decrease in the matrix ion signal, or matrix suppression. In this work, we found that saturation of the detector was one of the factors responsible for the above phenomena. As we decreased the detector gain, the upper limit of the linear dynamic range increased by as much as one order of magnitude. Even after a substantial decrease in the detector gain, however, the nonlinearity remained at a high analyte concentration, which we cannot account for at present. The method developed in this work can be useful for the quantitative imaging of analytes in heavily contaminated samples-
dc.publisherWiley-
dc.titleTracing the origin of the anomalous matrix suppression in matrix-assisted laser desorption ionization and extending the linear dynamic range during analyte quantification-
dc.title.alternativeTracing the origin of the anomalous matrix suppression in matrix-assisted laser desorption ionization and extending the linear dynamic range during analyte quantification-
dc.typeArticle-
dc.citation.titleBulletin of Korean Chemical Society-
dc.citation.number2-
dc.citation.endPage212-
dc.citation.startPage207-
dc.citation.volume39-
dc.contributor.affiliatedAuthorJeong Hee Moon-
dc.contributor.alternativeName송효인-
dc.contributor.alternativeName현택환-
dc.contributor.alternativeName김명수-
dc.contributor.alternativeName오주연-
dc.contributor.alternativeName문정희-
dc.identifier.bibliographicCitationBulletin of Korean Chemical Society, vol. 39, no. 2, pp. 207-212-
dc.identifier.doi10.1002/bkcs.11368-
dc.subject.keywordDetector saturation-
dc.subject.keywordLinear dynamic range-
dc.subject.keywordLiquid matrix-
dc.subject.keywordMatrix suppression-
dc.subject.keywordMatrix-assisted laser desorption ionization quantification-
dc.subject.localDetector saturation-
dc.subject.localLinear dynamic range-
dc.subject.localliquid matrix-
dc.subject.localLiquid matrix-
dc.subject.localMatrix suppression-
dc.subject.localMatrix-assisted laser desorption ionization quantification-
dc.description.journalClassY-
Appears in Collections:
Division of Bio Technology Innovation > Core Research Facility & Analysis Center > 1. Journal Articles
Files in This Item:
  • There are no files associated with this item.


Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.