Analyte quantity detection from lateral flow assay using a smartphone

Cited 50 time in scopus
Metadata Downloads

Full metadata record

DC FieldValueLanguage
dc.contributor.authorK H Foysal-
dc.contributor.authorSung Eun Seo-
dc.contributor.authorMin Ju Kim-
dc.contributor.authorOh Seok Kwon-
dc.contributor.authorJ W Chong-
dc.date.accessioned2020-02-07T16:30:22Z-
dc.date.available2020-02-07T16:30:22Z-
dc.date.issued2019-
dc.identifier.issn1424-8220-
dc.identifier.uri10.3390/s19214812ko
dc.identifier.urihttps://oak.kribb.re.kr/handle/201005/19109-
dc.description.abstractLateral flow assay (LFA) technology has recently received interest in the biochemical field since it is simple, low-cost, and rapid, while conventional laboratory test procedures are complicated, expensive, and time-consuming. In this paper, we propose a robust smartphone-based analyte detection method that estimates the amount of analyte on an LFA strip using a smartphone camera. The proposed method can maintain high estimation accuracy under various illumination conditions without additional devices, unlike conventional methods. The robustness and simplicity of the proposed method are enabled by novel image processing and machine learning techniques. For the performance analysis, we applied the proposed method to LFA strips where the target analyte is albumin protein of human serum. We use two sets of training LFA strips and one set of testing LFA strips. Here, each set consists of five strips having different quantities of albumin-10 femtograms, 100 femtograms, 1 picogram, 10 picograms, and 100 picograms. A linear regression analysis approximates the analyte quantity, and then machine learning classifier, support vector machine (SVM), which is trained by the regression results, classifies the analyte quantity on the LFA strip in an optimal way. Experimental results show that the proposed smartphone application can detect the quantity of albumin protein on a test LFA set with 98% accuracy, on average, in real time.-
dc.publisherMDPI-
dc.titleAnalyte quantity detection from lateral flow assay using a smartphone-
dc.title.alternativeAnalyte quantity detection from lateral flow assay using a smartphone-
dc.typeArticle-
dc.citation.titleSensors-
dc.citation.number21-
dc.citation.endPage4812-
dc.citation.startPage4812-
dc.citation.volume19-
dc.contributor.affiliatedAuthorSung Eun Seo-
dc.contributor.affiliatedAuthorMin Ju Kim-
dc.contributor.affiliatedAuthorOh Seok Kwon-
dc.contributor.alternativeNameFoysal-
dc.contributor.alternativeName서성은-
dc.contributor.alternativeName김민주-
dc.contributor.alternativeName권오석-
dc.contributor.alternativeName종조운-
dc.identifier.bibliographicCitationSensors, vol. 19, no. 21, pp. 4812-4812-
dc.identifier.doi10.3390/s19214812-
dc.subject.keywordLFA pad-
dc.subject.keywordLFA reader-
dc.subject.keywordanalyte detection-
dc.subject.keywordsmartphone-
dc.subject.localLFA pad-
dc.subject.localLFA reader-
dc.subject.localanalyte detection-
dc.subject.localsmartphone-
dc.subject.localSmartphone-
dc.description.journalClassY-
Appears in Collections:
Division of Research on National Challenges > Infectious Disease Research Center > 1. Journal Articles
Files in This Item:

Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.