Reusable surface amplified nanobiosensor for the sub PFU/mL level detection of airborne virus

Cited 10 time in scopus
Metadata Downloads

Full metadata record

DC FieldValueLanguage
dc.contributor.authorJ Shin-
dc.contributor.authorH R Kim-
dc.contributor.authorP K Bae-
dc.contributor.authorH Yoo-
dc.contributor.authorJ Kim-
dc.contributor.authorY Choi-
dc.contributor.authorA Kang-
dc.contributor.authorW S Yun-
dc.contributor.authorYong Beom Shin-
dc.contributor.authorJ Hwang-
dc.contributor.authorS Hong-
dc.date.accessioned2021-08-23T15:30:31Z-
dc.date.available2021-08-23T15:30:31Z-
dc.date.issued2021-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://oak.kribb.re.kr/handle/201005/24662-
dc.description.abstractWe developed a reusable surface-amplified nanobiosensor for monitoring airborne viruses with a sub-PFU/mL level detection limit. Here, sandwich structures consisted of magnetic particles functionalized with antibodies, target viruses, and alkaline phosphatases (ALPs) were formed, and they were magnetically concentrated on Ni patterns near an electrochemical sensor transducer. Then, the electrical signals from electrochemical markers generated by ALPs were measured with the sensor transducer, enabling highly-sensitive virus detection. The sandwich structures in the used sensor chip could be removed by applying an external magnetic field, and we could reuse the sensor transducer chip. As a proof of concepts, the repeated detection of airborne influenza virus using a single sensor chip was demonstrated with a detection limit down to a sub-PFU/mL level. Using a single reusable sensor transducer chip, the hemagglutinin (HA) of influenza A (H1N1) virus with different concentrations were measured down to 10 aM level. Importantly, our sensor chip exhibited reliable sensing signals even after more than 18 times of the repeated HA sensing measurements. Furthermore, airborne influenza viruses collected from the air could be measured down to 0.01 PFU/mL level. Interestingly, the detailed quantitative analysis of the measurement results revealed the degradation of HA proteins on the viruses after the air exposure. Considering the ultrasensitivity and reusability of our sensors, it can provide a powerful tool to help preventing epidemics by airborne pathogens in the future.-
dc.publisherSpringer-Nature Pub Group-
dc.titleReusable surface amplified nanobiosensor for the sub PFU/mL level detection of airborne virus-
dc.title.alternativeReusable surface amplified nanobiosensor for the sub PFU/mL level detection of airborne virus-
dc.typeArticle-
dc.citation.titleScientific Reports-
dc.citation.number0-
dc.citation.endPage16776-
dc.citation.startPage16776-
dc.citation.volume11-
dc.contributor.affiliatedAuthorYong Beom Shin-
dc.contributor.alternativeName신정현-
dc.contributor.alternativeName김형래-
dc.contributor.alternativeName배판기-
dc.contributor.alternativeName유하늘-
dc.contributor.alternativeName김정수-
dc.contributor.alternativeName최윤지-
dc.contributor.alternativeName강애연-
dc.contributor.alternativeName윤완S-
dc.contributor.alternativeName신용범-
dc.contributor.alternativeName황정호-
dc.contributor.alternativeName홍승훈-
dc.identifier.bibliographicCitationScientific Reports, vol. 11, pp. 16776-16776-
dc.identifier.doi10.1038/s41598-021-96254-2-
dc.description.journalClassY-
Appears in Collections:
Division of Research on National Challenges > Bionanotechnology Research Center > 1. Journal Articles
Files in This Item:
  • There are no files associated with this item.


Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.