Evaluation of the diagnostic accuracy of nasal cavity and nasopharyngeal swab specimens for SARS-CoV-2 detection via rapid antigen test according to specimen collection timing and viral load

Cited 16 time in scopus
Metadata Downloads

Full metadata record

DC FieldValueLanguage
dc.contributor.authorS Lee-
dc.contributor.authorK Widyasari-
dc.contributor.authorH R Yang-
dc.contributor.authorJ Jang-
dc.contributor.authorTaejoon Kang-
dc.contributor.authorS Kim-
dc.date.accessioned2022-03-28T15:31:29Z-
dc.date.available2022-03-28T15:31:29Z-
dc.date.issued2022-
dc.identifier.issn2075-4418-
dc.identifier.urihttps://oak.kribb.re.kr/handle/201005/25659-
dc.description.abstractThe rapid diagnosis of SARS-CoV-2 is an essential aspect in the detection and control of the spread of COVID-19. We evaluated the accuracy of the rapid antigen test (RAT) using samples from the nasal cavity and nasopharynx based on sample collection timing and viral load. We enrolled 175 patients, of which 71 patients and 104 patients had tested positive and negative, respectively, based on real time-PCR. Nasal cavity and nasopharyngeal swab samples were tested using STANDARD Q COVID-19 Ag tests (Q Ag, SD Biosensor, Korea). The sensitivity of the Q Ag test was 77.5% (95% confidence interval [CI], 67.8-87.2%) for the nasal cavity and 81.7% (95% [CI, 72.7-90.7%) for the nasopharyngeal specimens. The RAT results showed a substantial agreement between the nasal cavity and nasopharyngeal specimens (Cohen's kappa index = 0.78). The sensitivity of the RAT for nasal cavity specimens exceeded 89% for <5 days after symptom onset (DSO) and 86% for Ct of E and RdRp < 25. The Q Ag test performed fairly well, especially in the early DSO when a high viral load was present, and the nasal cavity swab can be considered an alternative site for the rapid diagnosis of COVID-19.-
dc.publisherMDPI-
dc.titleEvaluation of the diagnostic accuracy of nasal cavity and nasopharyngeal swab specimens for SARS-CoV-2 detection via rapid antigen test according to specimen collection timing and viral load-
dc.title.alternativeEvaluation of the diagnostic accuracy of nasal cavity and nasopharyngeal swab specimens for SARS-CoV-2 detection via rapid antigen test according to specimen collection timing and viral load-
dc.typeArticle-
dc.citation.titleDiagnostics-
dc.citation.number3-
dc.citation.endPage710-
dc.citation.startPage710-
dc.citation.volume12-
dc.contributor.affiliatedAuthorTaejoon Kang-
dc.contributor.alternativeName이승준-
dc.contributor.alternativeNameWidyasari-
dc.contributor.alternativeName양혜련-
dc.contributor.alternativeName장지은-
dc.contributor.alternativeName강태준-
dc.contributor.alternativeName김선주-
dc.identifier.bibliographicCitationDiagnostics, vol. 12, no. 3, pp. 710-710-
dc.identifier.doi10.3390/diagnostics12030710-
dc.subject.keywordSARS-CoV-2-
dc.subject.keywordCOVID-19 testing-
dc.subject.keywordRapid antigen test-
dc.subject.keywordNasal cavity-
dc.subject.keywordDetection-
dc.subject.localSARS-CoV-2-
dc.subject.localSARS-Cov-2-
dc.subject.localCOVID-19 testing-
dc.subject.localRapid antigen test-
dc.subject.localNasal cavity-
dc.subject.localdetection-
dc.subject.localDetection-
dc.description.journalClassY-
Appears in Collections:
Division of Research on National Challenges > Bionanotechnology Research Center > 1. Journal Articles
Files in This Item:
  • There are no files associated with this item.


Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.