DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kyeong-Ryoon Lee | - |
dc.contributor.author | J E Chang | - |
dc.contributor.author | Y J Chae | - |
dc.date.accessioned | 2022-09-29T16:32:32Z | - |
dc.date.available | 2022-09-29T16:32:32Z | - |
dc.date.issued | 2022 | - |
dc.identifier.issn | 0910-6340 | - |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/30394 | - |
dc.description.abstract | Drug interactions can induce significant clinical impacts, either by increasing adverse effects or by decreasing the therapeutic effect of drugs, and thus, need to be explored thoroughly. Clinically significant drug interactions can be induced by organic anion transporter 1 (OAT1) and OAT3 when concomitant medications competitively interact with the transporters. The purposes of this study were to develop and validate a sensitive and selective analytical method for 5-carboxyfluorescein (5-CF) and optimize the experimental conditions for interaction studies. An analytical method using high-performance liquid chromatography (HPLC) equipped with a fluorescence detector was validated for accuracy, precision, matrix effect, recovery, stability, dilutional integrity, and carry-over effect. In addition, the 5-CF concentration, incubation period, and washing conditions for interaction study were optimized. Using a valid analytical method and optimized conditions, we performed an interaction study for OAT1 and OAT3 using 26 test articles. Some of the test articles showed strong inhibitory potency for the transporters, with IC50 values close to or less than 10 μM. The valid analysis method and optimized systems developed in this study can be utilized to improve the predictability of drug interactions in humans and consequently aid in successful disease treatment by maintaining appropriate systemic exposures. | - |
dc.publisher | Japan Soc Analytical Chemistry | - |
dc.title | Sensitive and valid assay for reliable evaluation of drug interactions mediated by human organic anion transporter 1 and 3 using 5-carboxyfluorescein | - |
dc.title.alternative | Sensitive and valid assay for reliable evaluation of drug interactions mediated by human organic anion transporter 1 and 3 using 5-carboxyfluorescein | - |
dc.type | Article | - |
dc.citation.title | Analytical Sciences | - |
dc.citation.number | 10 | - |
dc.citation.endPage | 1357 | - |
dc.citation.startPage | 1347 | - |
dc.citation.volume | 38 | - |
dc.contributor.affiliatedAuthor | Kyeong-Ryoon Lee | - |
dc.contributor.alternativeName | 이경륜 | - |
dc.contributor.alternativeName | 장지은 | - |
dc.contributor.alternativeName | 채윤지 | - |
dc.identifier.bibliographicCitation | Analytical Sciences, vol. 38, no. 10, pp. 1347-1357 | - |
dc.identifier.doi | 10.1007/s44211-022-00166-8 | - |
dc.subject.keyword | Organic anion transporters (OATs) | - |
dc.subject.keyword | 5-carboxyfluorescein (5-CF) | - |
dc.subject.keyword | Drug interactions | - |
dc.subject.keyword | Method validation | - |
dc.subject.keyword | High-performance liquid chromatography (HPLC) | - |
dc.subject.local | Organic anion transporters (OATs) | - |
dc.subject.local | 5-carboxyfluorescein (5-CF) | - |
dc.subject.local | Drug interaction | - |
dc.subject.local | Drug interactions | - |
dc.subject.local | drug interaction | - |
dc.subject.local | drug interactions | - |
dc.subject.local | method validation | - |
dc.subject.local | Method validation | - |
dc.subject.local | High-performance liquid chromatography | - |
dc.subject.local | High-performance liquid chromatography (HPLC) | - |
dc.subject.local | high-performance liquid chromatography | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.