Comparison study of mouse brain tissue by using ToF-SIMS within static limits and hybrid SIMS beyond static limits (dynamic mode)

Cited 0 time in scopus
Metadata Downloads
Title
Comparison study of mouse brain tissue by using ToF-SIMS within static limits and hybrid SIMS beyond static limits (dynamic mode)
Author(s)
H K Shon; J K Son; S Y Lee; Jeong Hee Moon; Ga Seul Lee; Kyoung Shim Kim; T G Lee
Bibliographic Citation
Biointerphases, vol. 18, no. 3, pp. 031005-031005
Publication Year
2023
Abstract
In the study of degenerative brain diseases, changes in lipids, the main component of neurons, are particularly important because they are used as indicators of pathological changes. One method for the sensitive measurement of biomolecules, especially lipids, is time-of-flight secondary ion mass spectrometry (ToF-SIMS) using pulsed argon cluster ions. In this study, biomolecules including various lipids present in normal mouse brain tissue were measured using ToF-SIMS equipped with pulsed argon cluster primary ions. Based on the ToF-SIMS measurement results, hybrid SIMS (OrbiSIMS), which is a ToF-SIMS system with the addition of an orbitrap mass analyzer, was used to directly identify the biomolecules by the region in the real tissue samples. For this, the results of ToF-SIMS, which measured the tissue samples from a single mouse brain within static limits, were compared with those from OrbiSIMS measured beyond the static limits in terms of the differences in molecular profiling. From this analysis, two types of positive and negative ions were selected for identification, with the OrbiSIMS MS/MS results indicating that the positive ions were glycerophosphocholine and the negative ions were glycerophosphoinositol and sulfatide, a sphingolipid. Then, to confirm the identification of the molecular candidates, lipids were extracted from mirror image tissue samples, and LC-MS/MS also using an orbitrap mass analyzer was performed. As a result, the direct identification of molecular candidate groups distributed in particular regions of the tissue samples via OrbiSIMS was found to be consistent with the identification results by LC-MS/MS for extracted samples.
ISSN
1934-8630
Publisher
Amer Inst Phys
DOI
http://dx.doi.org/10.1116/6.0002613
Type
Article
Appears in Collections:
Division of Bio Technology Innovation > Core Research Facility & Analysis Center > 1. Journal Articles
Ochang Branch Institute > Division of National Bio-Infrastructure > Laboratory Animal Resource & Research Center > 1. Journal Articles
Files in This Item:
  • There are no files associated with this item.


Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.