DC Field | Value | Language |
---|---|---|
dc.contributor.author | J H Jeung | - |
dc.contributor.author | H Han | - |
dc.contributor.author | S H Jang | - |
dc.contributor.author | Chang Yeol Lee | - |
dc.contributor.author | J K Ahn | - |
dc.date.accessioned | 2024-03-29T16:33:01Z | - |
dc.date.available | 2024-03-29T16:33:01Z | - |
dc.date.issued | 2024 | - |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/33923 | - |
dc.description.abstract | In this study, we present a one-pot, one-step, label-free miRNA detection method through a structural transition of a specially designed dumbbell-shape probe, initiating a rolling circle transition (RCT). In principle, target miRNA binds to right loop of the dumbbell probe (DP), which allows structural change of the DP to circular form, exposing a sequence complementary to the T7 promoter (T7p) previously hidden within the stem. This exposure allows T7 RNA polymerase to initiate RCT, producing a repetitive Mango aptamer sequence. TO1-biotin, fluorescent dye, binds to the aptamer, inducing a detectable enhancement of fluorescence intensity. Without miR-141, the DP stays closed, RCT is prevented, and the fluorescence intensity remains low. By employing this novel strategy, target miRNA was successfully identified with a detection of 73 pM and a dynamic linear range of 0-10 nM. Additionally, the method developed enables one-pot, one-step, and label-free detection of miRNA, demonstrating potential for point-of-care testing (POCT) applications. Furthermore, the practical application of the designed technique was demonstrated by reliably detecting the target miRNA in the human serum sample. We also believe that the conceived approach could be widely used to detect not only miRNAs but also diverse biomolecules by simply replacing the detection probe. | - |
dc.publisher | Elsevier | - |
dc.title | One-pot, one-step, label-free miRNA detection method based on the structural transition of dumbbell probe | - |
dc.title.alternative | One-pot, one-step, label-free miRNA detection method based on the structural transition of dumbbell probe | - |
dc.type | Article | - |
dc.citation.title | Talanta | - |
dc.citation.number | 0 | - |
dc.citation.endPage | 125944 | - |
dc.citation.startPage | 125944 | - |
dc.citation.volume | 274 | - |
dc.contributor.affiliatedAuthor | Chang Yeol Lee | - |
dc.contributor.alternativeName | 정재훈 | - |
dc.contributor.alternativeName | 한효구 | - |
dc.contributor.alternativeName | 장세희 | - |
dc.contributor.alternativeName | 이창열 | - |
dc.contributor.alternativeName | 안준기 | - |
dc.identifier.bibliographicCitation | Talanta, vol. 274, pp. 125944-125944 | - |
dc.identifier.doi | 10.1016/j.talanta.2024.125944 | - |
dc.subject.keyword | miRNA | - |
dc.subject.keyword | Dumbbell probe | - |
dc.subject.keyword | Structural transition | - |
dc.subject.keyword | Light-up RNA aptamer | - |
dc.subject.keyword | Rolling circle transcription (RCT) | - |
dc.subject.keyword | Biosensor | - |
dc.subject.local | miRNA | - |
dc.subject.local | MicroRNA | - |
dc.subject.local | MicroRNA (miRNA) | - |
dc.subject.local | Light-up RNA aptamer | - |
dc.subject.local | Biosensor | - |
dc.subject.local | Biosensors | - |
dc.subject.local | biosensor | - |
dc.subject.local | biosensors | - |
dc.subject.local | Bio-sensor | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.