TRPA1 nanovesicle-conjugated receptonics for rapid biocide screening

Cited 0 time in scopus
Metadata Downloads

Full metadata record

DC FieldValueLanguage
dc.contributor.authorK H Kim-
dc.contributor.authorJ Kwak-
dc.contributor.authorS E Seo-
dc.contributor.authorSiyoung Ha-
dc.contributor.authorG J Kim-
dc.contributor.authorS Lee-
dc.contributor.authorS J Sim-
dc.contributor.authorY K Lee-
dc.contributor.authorN L Tran-
dc.contributor.authorS J Oh-
dc.contributor.authorW K Kim-
dc.contributor.authorH S Song-
dc.contributor.authorO S Kwon-
dc.date.accessioned2024-08-05T16:33:04Z-
dc.date.available2024-08-05T16:33:04Z-
dc.date.issued2024-
dc.identifier.issn0304-3894-
dc.identifier.urihttps://oak.kribb.re.kr/handle/201005/35553-
dc.description.abstractAlthough biocides are important materials in modern society and help protect human health and the environment, increasing exposure to combined biocides can cause severe side effects in the human body, such as lung fibrosis. In this study, we developed a receptonics system to screen for biocides in combined household chemical products based on biocides. The system contains transient receptor potential ankyrin 1 (TRPA1) nanovesicles (NVs) to sense biocides based on pain receptors and a side-gated field-effect transistor (SGFET) using a single-layer graphene (SLG) micropattern channel. The binding affinities between the TRPA1 receptor and the various biocides were estimated by performing biosimulation and using a calcium ion (Ca2+) assay, and the sensitivity of the system was compared with that of TRPA1 NV receptonics systems. Based on the results of the TRPA1 NV receptonics system, the antagonistic and potentiation effects of combined biocides and household chemical products depended on the concentration. Finally, the TRPA1 NV receptonics system was applied to screen for biocides in real products, and its performance was successful. Based on these results, the TRPA1 NV receptonics system can be utilized to perform risk evaluations and identify biocides in a simple and rapid manner.-
dc.publisherElsevier-
dc.titleTRPA1 nanovesicle-conjugated receptonics for rapid biocide screening-
dc.title.alternativeTRPA1 nanovesicle-conjugated receptonics for rapid biocide screening-
dc.typeArticle-
dc.citation.titleJournal of Hazardous Materials-
dc.citation.number0-
dc.citation.endPage135282-
dc.citation.startPage135282-
dc.citation.volume477-
dc.contributor.affiliatedAuthorSiyoung Ha-
dc.contributor.alternativeName김경호-
dc.contributor.alternativeName곽지성-
dc.contributor.alternativeName서성은-
dc.contributor.alternativeName하시영-
dc.contributor.alternativeName김경지-
dc.contributor.alternativeName이상우-
dc.contributor.alternativeName심상준-
dc.contributor.alternativeName이연경-
dc.contributor.alternativeNameTran-
dc.contributor.alternativeName오승자-
dc.contributor.alternativeName김우근-
dc.contributor.alternativeName송현석-
dc.contributor.alternativeName권오석-
dc.identifier.bibliographicCitationJournal of Hazardous Materials, vol. 477, pp. 135282-135282-
dc.identifier.doi10.1016/j.jhazmat.2024.135282-
dc.subject.keywordReceptonics-
dc.subject.keywordBioelectronics-
dc.subject.keywordBiocidescreening-
dc.subject.keywordTRPA1-
dc.subject.keywordAOP-
dc.subject.keywordReal-timemonitoring-
dc.subject.localreceptonics-
dc.subject.localReceptonics-
dc.description.journalClassY-
Appears in Collections:
1. Journal Articles > Journal Articles
Files in This Item:
  • There are no files associated with this item.


Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.