DC Field | Value | Language |
---|---|---|
dc.contributor.author | S Lee | - |
dc.contributor.author | Bong Hyun Chung | - |
dc.contributor.author | S H Kang | - |
dc.date.accessioned | 2017-04-19T09:11:11Z | - |
dc.date.available | 2017-04-19T09:11:11Z | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 1567-1739 | - |
dc.identifier.uri | 10.1016/j.cap.2007.04.041 | ko |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/8508 | - |
dc.description.abstract | This study examined the applicability of a prism-type simultaneous dual-color total internal reflection fluorescence microscopy (TIRFM) system for the simultaneous detection of nano biomolecules on nanoarray biochips at the single-molecule level. The dual-color TIRFM system with two individual laser beams and a high-sensitivity camera was used for the simultaneous dual-color detection of two different nano beads (i.e. 20 nm yellow-green and crimson fluorescent FluoSpheres beads), and single-protein molecules labeled with different fluorescent dyes (i.e. actin from rabbit muscle conjugated with Alexa Fluor® 488 and Alexa Fluor® 633 goat anti-rabbit IgG) without a time-delay and the need to move the sample. When this system was applied to two different single-protein molecules labeled with different fluorescent dyes on the GPTS/CHI/GA-modified glass nanoarray chip, the full images of the biomolecules at the single-molecule level were obtained simultaneously in two different colors using a Dual-View™. The dual-color TIRFM system is quite suitable for the biological imaging at the single-molecule level on nanoarray biochips. This study provides a benchmark for directly monitoring the interactions and detecting the colocalization of two different nano biomolecules, and can be applied to the development of a nanoarray biochip at the single-molecule level. | - |
dc.publisher | Elsevier | - |
dc.title | Dual-color prism-type TIRFM system for direct detection of single-biomolecules on nanoarray biochips | - |
dc.title.alternative | Dual-color prism-type TIRFM system for direct detection of single-biomolecules on nanoarray biochips | - |
dc.type | Article | - |
dc.citation.title | Current Applied Physics | - |
dc.citation.number | 6 | - |
dc.citation.endPage | 705 | - |
dc.citation.startPage | 700 | - |
dc.citation.volume | 8 | - |
dc.contributor.affiliatedAuthor | Bong Hyun Chung | - |
dc.contributor.alternativeName | 이승아 | - |
dc.contributor.alternativeName | 정봉현 | - |
dc.contributor.alternativeName | 강성호 | - |
dc.identifier.bibliographicCitation | Current Applied Physics, vol. 8, no. 6, pp. 700-705 | - |
dc.identifier.doi | 10.1016/j.cap.2007.04.041 | - |
dc.subject.keyword | Dual-color TIRFM | - |
dc.subject.keyword | Nanoarray biochip | - |
dc.subject.keyword | Single-molecule detection | - |
dc.subject.local | Dual-color TIRFM | - |
dc.subject.local | dual-color TIRFM | - |
dc.subject.local | Nanoarray biochip | - |
dc.subject.local | single-molecule detection | - |
dc.subject.local | Single-molecule detection | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.