DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hyun Kyu Park | - |
dc.contributor.author | Sang Jeon Chung | - |
dc.contributor.author | H G Park | - |
dc.contributor.author | J H Cho | - |
dc.contributor.author | Moonil Kim | - |
dc.contributor.author | Bong Hyun Chung | - |
dc.date.accessioned | 2017-04-19T09:11:27Z | - |
dc.date.available | 2017-04-19T09:11:27Z | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.uri | 10.1016/j.bios.2008.06.017 | ko |
dc.identifier.uri | https://oak.kribb.re.kr/handle/201005/8556 | - |
dc.description.abstract | Polydiacetylenes (PDAs), which possess unique properties that allow them to change color in response to environmental changes such as variations in pH, temperature, and molecular binding, have been widely investigated as signal transducers in biosensor applications. Most PDA-based sensors reported to date have been evaluated largely on the basis of their ability to detect purified samples, however, and their specificity has rarely been tested. In this study, novel PDAs fabricated on polyvinylidene fluoride (PVDF) strips by photoreaction of composite diacetylene self-assemblies were developed as biosensors, and nonspecific binding to off-target biomolecules was assessed. A mixed PDA surface containing biotin and ethanolamide bound the target, i.e., streptavidin, more specifically than did biotin alone. The optimized PDA biosensor exhibited approximately 2850-fold higher selectivity for streptavidin relative to bovine serum albumin controls. A PDA biosensor that was further prepared showed distinctive signals for the urine of diabetic patients compared to urine samples from healthy/non-diabetic person due to the concentration of microalbuminuria. To our knowledge, this is the first strip-type biosensor fabricated with PDAs and the first PDA-based biosensor that can effectively overcome the problem of nonspecific binding. | - |
dc.publisher | Elsevier | - |
dc.title | Mixed self-assembly of polydiacetylenes for highly specific and sensitive strip biosensors | - |
dc.title.alternative | Mixed self-assembly of polydiacetylenes for highly specific and sensitive strip biosensors | - |
dc.type | Article | - |
dc.citation.title | Biosensors & Bioelectronics | - |
dc.citation.number | 3 | - |
dc.citation.endPage | 484 | - |
dc.citation.startPage | 480 | - |
dc.citation.volume | 24 | - |
dc.contributor.affiliatedAuthor | Hyun Kyu Park | - |
dc.contributor.affiliatedAuthor | Sang Jeon Chung | - |
dc.contributor.affiliatedAuthor | Moonil Kim | - |
dc.contributor.affiliatedAuthor | Bong Hyun Chung | - |
dc.contributor.alternativeName | 박현규 | - |
dc.contributor.alternativeName | 정상전 | - |
dc.contributor.alternativeName | 박현규 | - |
dc.contributor.alternativeName | 조재형 | - |
dc.contributor.alternativeName | 김문일 | - |
dc.contributor.alternativeName | 정봉현 | - |
dc.identifier.bibliographicCitation | Biosensors & Bioelectronics, vol. 24, no. 3, pp. 480-484 | - |
dc.identifier.doi | 10.1016/j.bios.2008.06.017 | - |
dc.subject.keyword | Mixed self-assembly | - |
dc.subject.keyword | Nonspecific binding | - |
dc.subject.keyword | Polydiacetylene | - |
dc.subject.keyword | Strip biosensor | - |
dc.subject.local | Mixed self-assembly | - |
dc.subject.local | Nonspecific binding | - |
dc.subject.local | nonspecific binding | - |
dc.subject.local | Polydiacetylene | - |
dc.subject.local | polydiacetylene | - |
dc.subject.local | Strip biosensor | - |
dc.description.journalClass | Y | - |
There are no files associated with this item.
Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.