Determination of motolimod concentration in rat plasma by liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study

Cited 6 time in scopus
Metadata Downloads
Title
Determination of motolimod concentration in rat plasma by liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
Author(s)
Y G Ji; Y M Shin; J W Jeong; H I Choi; S W Lee; J H Lee; Kyeong-Ryoon Lee; T S Koo
Bibliographic Citation
Journal of Pharmaceutical and Biomedical Analysis, vol. 179, pp. 112987-112987
Publication Year
2020
Abstract
Motolimod (VTX-2337) is an agonist of toll-like receptor 8. In this study, a novel and sensitive liquid chromatography-tandem mass spectrometry method was developed for quantifying motolimod in rat plasma and subsequently used in a pharmacokinetic study. Proteins were precipitated from plasma samples using acetonitrile prior to the analysis. GS-9620 was used as an internal standard. High-performance liquid chromatography was performed using a Spursil C18-EP column (3 μm, 50×2.1mm). Aqueous ammonium formate and acetonitrile were used as the mobile phase. Motolimod was detected using an electrospray ionization interface under multiple reaction monitoring conditions in the positive ion mode. The developed method produced a linear correlation over a concentration range of 1-1000 ng/mL (r=0.9944). Intra- and inter-day precision values ranged from 4.8%-10.7% (the lower limit of quantification precision value was 16.3 %), whereas intra- and inter-day accuracy values ranged from 0.3%-9.1 %. The mean recovery of motolimod from rat plasma was 109.4 %. Additionally, motolimod was found to be stable under various conditions (three freeze-thaw cycles, 6-h storage at room temperature, short- and long-term stability tests, and processing). The developed method was successfully used in a pharmacokinetic study in rats. Motolimod showed non-linear pharmacokinetics following its intravenous administration to rats at 0.6-6?mg/kg. Additionally, very low exposure (<1 %) was obtained following oral administration of the drug to rats. The results also showed that motolimod has a low metabolic stability in the liver microsomes and exhibits extensive binding to the plasma proteins.
Keyword
Liquid chromatography-tandem mass spectrometryPharmacokineticsToll-like receptor 8VTX-2337
ISSN
0731-7085
Publisher
Elsevier
Full Text Link
http://dx.doi.org/10.1016/j.jpba.2019.112987
Type
Article
Appears in Collections:
Ochang Branch Institute > Division of National Bio-Infrastructure > Laboratory Animal Resource & Research Center > 1. Journal Articles
Files in This Item:
  • There are no files associated with this item.


Items in OpenAccess@KRIBB are protected by copyright, with all rights reserved, unless otherwise indicated.